Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
JACC Cardiovasc Interv ; 17(6): 727-737, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38456879

RESUMO

BACKGROUND: Coronary re-engagement after transcatheter aortic valve replacement (TAVR) using self-expanding transcatheter heart valves (THVs) systematically implanted using commissural alignment (CA) techniques has been poorly investigated. OBJECTIVES: The aim of this study was to evaluate unsuccessful coronary cannulation, and its predictors, after TAVR using self-expanding devices implanted using CA techniques. METHODS: RE-ACCESS 2 (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent 2) was an investigator-driven, single-center, prospective study that enrolled consecutive TAVR patients receiving Evolut and ACURATE THVs implanted using CA techniques. The primary endpoint was unsuccessful coronary cannulation after TAVR. The secondary endpoint was the identification of postprocedural predictors of unfeasible, selective coronary ostia re-engagement on computed tomographic angiography performed after TAVR. RESULTS: Among 127 patients enrolled from September 2021 to December 2022, 7 (5.5%) had unsuccessful coronary cannulation after TAVR, and 6 of them received Evolut THVs (7.5% vs 2.3%; P = 0.26). Failure of left coronary artery cannulation was similar between Evolut and ACURATE THVs (2.5% vs 2.1%; P = 1.00), whereas that of right coronary artery cannulation was prevalent in the Evolut group (6.3% vs 0.0%; P = 0.16). Coronary overlap was associated with the inability to selectively cannulate the right coronary artery (OR: 5.6; 95% CI: 1.2-25.8; P = 0.03), but not in ACURATE recipients (P = 0.39). Severe misalignment of Evolut THVs was associated with the inability to selectively cannulate both coronary arteries (OR: 24.7; 95% CI: 1.9-312.9; P = 0.01). CONCLUSIONS: Unsuccessful coronary cannulation after TAVR using self-expanding THVs implanted using CA techniques was reported in 5.5% of cases, with the majority involving the Evolut THV. Commissural misalignment affected coronary cannulation after TAVR mostly in Evolut recipients.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Fatores de Risco , Desenho de Prótese , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Cateterismo
2.
JACC Cardiovasc Interv ; 17(6): 715-726, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38456886

RESUMO

BACKGROUND: Coronary alignment is proposed as an alternative to commissural alignment for reducing coronary overlap during transcatheter aortic valve replacement (TAVR). However, largescale studies are lacking. OBJECTIVES: This study aimed to determine the incidence of coronary overlap with commissural vs coronary alignment using computed tomography (CT) simulation in patients undergoing TAVR evaluation. METHODS: In 1,851 CT scans of native aortic stenosis patients undergoing TAVR evaluation (April 2018 to December 2022),virtual valves simulating commissural and coronary alignment were superimposed on axial aortic root images. Coronary overlap was assessed based on the angular gap between coronary artery origin and the nearest transcatheter heart valve commissure, categorized as severe (≤15°), moderate (15°-30°), mild (30°-45°), and no-overlap (45°-60°). RESULTS: The overall incidence of moderate/severe and severe overlap with either coronary artery remained rare with either coronary or commissural alignment (coronary 0.52% left, 0.52% right; commissural 0.30% left, 3.27% right). Comparing techniques, coronary alignment reduced moderate/severe overlap only for the right coronary artery (0.38% vs 2.97%; P <0.0001). For the left coronary artery, both techniques showed similar moderate/severe overlap, but commissural alignment had significantly higher no-overlap rates (91.1% vs 84.9%; P < 0.0001). Fluoroscopic angle during valve deployment was strongly correlated between commissural and coronary alignment (r = 0.80; P < 0.001). CONCLUSIONS: Using CT simulation, the incidence of coronary overlap with transcatheter heart valve-commissure is rare with commissural alignment. Coronary alignment reduced right coronary overlap, whereas commissural alignment had higher rates of no left coronary overlap. Coronary alignment should be reserved only when commissural alignment results in severe coronary overlap.


Assuntos
Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Tomografia Computadorizada Multidetectores
3.
JACC Case Rep ; 29(4): 102190, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38379652

RESUMO

A simple and reproducible technique to achieve commissural alignment during transcatheter aortic valve replacement with the Allegra valve is described. Slight rotation of the system before system insertion is necessary. Moreover, thanks to its permaflow system (Biosensors) and its radiopaque markings, small adjustments before valve deployment can be made to reassess correct alignment.

5.
Int J Cardiol ; 395: 131572, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37913960

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) showed safety and efficacy in patients with severe aortic stenosis. Commissural alignment (CA) during TAVR has the potential to reduce the impact of the prostheses on accessibility of coronary arteries, as misalignment of the neocommissures could cause partial overlap with coronary ostia. Therefore, the aim of this study was to investigate the impact of CA on coronary overlap rates. METHODS: We examined the techniques of CA and their impact on coronary access. Eligible studies were searched for on Pubmed, SCOPUS and DOAJ and selected using PRISMA guidelines. The primary endpoint was the incidence of a severe coronary overlap or failed coronary re-access. Results of the analysis are expressed as Risk Ratio (RR) with 95% CI. RESULTS: Four studies were included in this analysis. In these, 681 patients underwent TAVR with CA and 210 underwent TAVR without CA. We examined Evolut valves and Acurate Neo valves. The primary endpoint occurred in 138 patients undergoing TAVR with CA and in 154 patients without CA (RR = 0.279; 95% CI 0.201-0.386; p < 0.001). Neither prosthesis-related, nor patient-related factors had a significant interaction with the measured effect. CONCLUSIONS: Commissural alignment was associated with significantly lower rates of commissure-to-coronary ostia overlap and failure of coronary access. Consequently, a modified insertion technique could reduce coronary overlap and coronary occlusion, particularly in supra-annular valves. Therefore, controlled orientation of prostheses by CA during TAVR could favour coronary access, especially in younger patients that could require coronary re-access after TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento , Fatores de Risco
6.
Cardiovasc Diagn Ther ; 13(3): 487-495, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37405016

RESUMO

Background: Previous studies have shown that neo-commissural orientation of transcatheter heart valve (THV) can influence coronary obstruction during transcatheter aortic valve replacement (TAVR), long-term durability of THV, and coronary artery access for reintervention after TAVR. Specific initial orientations of Evolut R/Pro and Acurate Neo aortic valves can improve commissural alignment. However, the method of achieving commissural alignment with the Venus-A valve remains unknown. Therefore, this study aimed to evaluate the extent of commissural and coronary alignment of the Venus-A self-expanding valve after TAVR using a standard system delivery technique. Methods: A retrospective cross-sectional study was performed. At the time of enrollment, patients who underwent pre- and post-procedural electrocardiographically-gated contrast-enhanced CT with a second-generation 64-row multidetector scanner were selected for the study. Commissural alignment was categorized as aligned (0-15° angle deviation), mild (15-30°), moderate (30-45°), or severe (45-60°) commissural misalignment (CMA). Coronary alignment was categorized as having no coronary overlap (CO) (>35°), moderate CO (20-35°), or severe CO (≤20°). The results were represented as proportions to assess the extent of commissural and coronary alignment. Results: Forty-five TAVR patients were ultimately included in the analysis. THVs were shown to be randomly implanted: 20.0% of THVs were aligned, 33.3% had mild CMA, 26.7% had moderate CMA, and 20.0% had severe CMA. The incidence of severe CO was 24.4% with the left main coronary artery, 28.9% with the right coronary artery, 6.7% with both coronary arteries, and 46.7% with one or both coronary arteries. Conclusions: The results showed that commissural or coronary alignment could not be achieved with the Venus-A valve using a standard system delivery technique. Therefore, specific methods to attain alignment with the Venus-A valve need to be identified.

7.
JACC Cardiovasc Interv ; 16(13): 1626-1635, 2023 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-37438029

RESUMO

BACKGROUND: The latest-generation Evolut FX TAVR system (Medtronic) offers several potential design improvements over its predecessors, but early reported experience has been limited. OBJECTIVES: This study sought to report our multicenter, limited market release, first-in-human experience of transcatheter aortic valve replacement (TAVR) with the Evolut FX system and compare it with a single-center PRO+ (Medtronic) experience. METHODS: From June 27 to September 16, 2022, 226 consecutive patients from 9 US centers underwent transfemoral TAVR with the Evolut FX system for native aortic stenosis (89.4%) or prosthetic valve degeneration (10.6%). Commissural alignment was defined as 0° to 30° between native and FX commissures. Patient, anatomical, and procedural characteristics were retrospectively reviewed, and 30-day clinical and echocardiographic outcomes per Valve Academic Research Consortium-3 definitions were reported. RESULTS: Of 226 patients, 34.1% were low risk, 4% had a bicuspid valve, and 11.5% had a horizontal root (≥60°). Direct Inline sheath (Medtronic) was used in 67.6% and Lunderquist stiff wire (Cook Medical) in 35.4% of cases. Optimal hat marker orientation during deployment was achieved in 98.4%, with commissural alignment in 96.5%. At 30 days, 14.3% mild, 0.9% moderate, and no severe paravalvular leak were observed. Compared with the Evolut PRO+ experience from 1 center, FX had a more symmetrical implantation with shallower depth at the left coronary cusp (P < 0.001), fewer device recaptures (26.1% vs 39.5%; P = 0.004), and improved commissural alignment (96.5% vs 80.2%; P < 0.001). CONCLUSIONS: The Evolut FX system demonstrated favorable 30-day outcomes with a significant improvement over PRO+ in achieving commissural alignment, fewer device recaptures, and more symmetrical implantation. These features may benefit younger patients undergoing TAVR with the supra-annular, self-expanding valve, where lifetime management would be important.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Catéteres
8.
Front Cardiovasc Med ; 10: 1154556, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37153454

RESUMO

Transcatheter aortic valve replacement (TAVR) indications recently extended to lower surgical risk patients with longer life expectancy. Commissural alignment (CA) is one of the emerging concepts and is becoming one of the cornerstones of the TAVR procedure in a patient with increased longevity. Indeed, CA may improve transcatheter heart valve (THV) hemodynamics, future coronary access, and repeatability. The definition of CA has been recently standardized by the ALIGN-TAVR consortium using a four-tier scale based on CT analysis. Progress has been made during the index TAVR procedure to optimize CA, especially with self-expandable platforms. Indeed, specific delivery catheter orientation, THV rotation, and computed-tomography-derived views have been proposed to achieve a reasonable degree of CA. Recent data demonstrate feasibility, safety, and a significant reduction in coronary overlap using these techniques, especially with self-expandable platforms. This review provides an overview of THV CA including assessment methods, alignment techniques during the index TAVR procedure with different THV platforms, the clinical impact of commissural misalignment, and challenging situations for CA.

9.
JACC Cardiovasc Interv ; 16(10): 1192-1204, 2023 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-37225290

RESUMO

BACKGROUND: Data regarding the impact of high transcatheter heart valve (THV) implantation on coronary access after transcatheter aortic valve replacement (TAVR) as assessed by postimplantation computed tomography (CT) are scarce. OBJECTIVES: The authors sought to assess the impact of high THV implantation on coronary access after TAVR. METHODS: We included 160 and 258 patients treated with Evolut R/PRO/PRO+ and SAPIEN 3 THVs, respectively. In the Evolut R/PRO/PRO+ group, the target implantation depth was 1 to 3 mm using the cusp overlap view with commissural alignment technique for the high implantation technique (HIT), whereas it was 3 to 5 mm using 3-cusp coplanar view for the conventional implantation technique (CIT). In the SAPIEN 3 group, the HIT employed the radiolucent line-guided implantation, whereas the central balloon marker-guided implantation was used for the CIT. Post-TAVR CT was performed to analyze coronary accessibility. RESULTS: HIT reduced the incidence of new conduction disturbances after TAVR for both THVs. In the Evolut R/PRO/PRO+ group, post-TAVR CT showed that the HIT group had a higher incidence of the interference of THV skirt (22.0% vs 9.1%; P = 0.03) and a lower incidence of the interference of THV commissural posts (26.0% vs 42.7%; P = 0.04) with access to 1 or both coronary ostia compared with the CIT group. These incidences were similar between the HIT and CIT groups in the SAPIEN 3 group (THV skirt: 0.9% vs 0.7%; P = 1.00; THV commissural tabs: 15.7% vs 15.3%; P = 0.93). In both THVs, CT-identified risk of sinus sequestration in TAVR-in-TAVR was significantly higher in the HIT group compared with the CIT group (Evolut R/PRO/PRO+ group: 64.0% vs 41.8%; P = 0.009; SAPIEN 3 group: 17.6% vs 5.3%; P = 0.002). CONCLUSIONS: High THV implantation substantially reduced conduction disturbances after TAVR. However, post-TAVR CT revealed that there is a risk for unfavorable future coronary access after TAVR and sinus sequestration in TAVR-in-TAVR. (Impact of High Implantation of Transcatheter Heart Valve during Transcatheter Aortic Valve Replacement on Future Coronary Access; UMIN000048336).


Assuntos
Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Tomografia Computadorizada por Raios X
11.
J Clin Med ; 12(6)2023 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-36983139

RESUMO

Transcatheter aortic valve implantation (TAVR) is the first therapeutic option for elderly patients with severe symptomatic aortic stenosis, and indications are steadily expanding to younger patients and subjects with lower surgical risk and longer life expectancy. Commissural alignment between native and transcatheter valves facilitates coronary access after TAVR and is thus considered a procedural goal, allowing long-term management of coronary artery disease. Moreover, commissural alignment may potentially have a positive impact on transvalvular hemodynamic and valve durability. This review focus on technical hints to achieve commissural alignment and current evidence for different transcatheter aortic valves.

12.
JACC Cardiovasc Interv ; 16(6): 670-677, 2023 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-36990556

RESUMO

BACKGROUND: Commissural alignment has become an important topic in transcatheter aortic valve replacement (TAVR) because it may improve coronary access, facilitate future valve procedures, and possibly improve valve durability. The efficacy of commissural alignment with ACURATE neo2 has not yet been shown in a large population. OBJECTIVES: The authors sought to determine the feasibility and success of attempting commissural alignment in an unselected TAVR population treated with the ACURATE neo2 prosthetic heart valve. METHODS: A total of 170 consecutive patients underwent TAVR with a dedicated implantation technique to align the TAVR valve to the native valve. Using right-left overlap and 3-cusp views, valve orientation was adjusted by rotation of the unexpanded valve at the level of the aortic root. Effectiveness was assessed postprocedure as the degree of misalignment determined by analyzing fluoroscopic valve orientation to corresponding cusp orientation on preprocedural computed tomography. Safety endpoints included mortality, stroke/transient ischemic attack, and additional complications through 30 days. RESULTS: Of 170 patients, 167 (98.2%) could be analyzed for alignment, and all 170, for safety outcomes. Most patients (97%) had successful alignment (≤ mild misalignment), with 80% with commissural alignment, while the degrees of misalignment were 17% mild, 1.2% moderate, 1.8% severe. CONCLUSIONS: In this large evaluation of a commissural alignment technique, alignment was achieved in nearly all patients without safety concerns or impact to procedure duration. Commissural alignment appears effective and safe across all patients with this novel technique.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Fatores de Risco , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Tomografia Computadorizada Multidetectores
14.
Rev. esp. cardiol. (Ed. impr.) ; 76(1): 19-24, Ene-Feb. 2023. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-214447

RESUMO

Introducción y objetivos: Nuestro objetivo fue describir la factibilidad y resultados preliminares de una estrategia de alineamiento comisural preciso (ACP) con implante percutáneo de válvula aórtica balón-expandible. Métodos: Se analizó la relación entre las comisuras nativas y las neocomisuras en 10 pacientes consecutivos con estenosis aórtica grave trivalva y sintomática tras orientar el implante de TAVI basándose en la tomografía computarizada (TC) a través de un programa de análisis específicamente desarrollado. El ACP se predijo en base a modelos in silico que permitieron estimar cuantos grados había que girar la prótesis en el momento del crimpado. El grado de ACP y de solapamiento con los ostium coronarios se midió mediante TC al mes. Se recogieron gradientes transvalvulares y fuga perivalvular. Resultados: El mal alineamiento medio fue de 16,7±8°. Cuatro pacientes presentaron mal alineamiento ligero, pero ninguno moderado o grave. El análisis in silico predijo la posición final de las neocomisuras con un coeficiente de correlación de 0,983 (IC95%, 0,966-0,992), p <0,001. Se produjo solapamiento coronario severo con el ostium de la coronaria derecha en 3 casos en relación con excentricidad de su origen, pero en ningún caso con el ostium coronario izquierdo. El gradiente transaórtico medio fue de 6,1±3,3mmHg y no hubo casos de fuga perivalvular moderada o grave. Conclusiones: Es posible calcular una rotación paciente-específica de la prótesis balón-expandible en el momento del crimpado basándose en la TC preprocedimiento. De este modo, se logró evitar el mal alineamiento moderado o grave de las neo-comisuras y el solapamiento con el ostium coronario izquierdo en todos los casos.(AU)


Introduction and objectives: We aimed to describe the feasibility and preliminary outcomes of commissural alignment (CA) for the balloon-expandable transcatheter heart valve. Methods: The relationship among native commissures and transcatheter aortic valve implantation neocommissures was analyzed in 10 consecutive patients with tricuspid severe aortic stenosis undergoing transcatheter aortic valve implantation after guided implantation based on computed tomography analysis with a self-developed software. CA was predicted by in silico bio-modelling in the 10 patients and the calculated rotation was applied during crimping. Degrees of CA and coronary overlap (CO) were measured through 1-month follow up computed tomography. Transvalvular residual gradients and the rate of paravalvular leak were also analyzed. Results: Mean commissural misalignment was 16.7±8°. Four patients showed mild misalignment but none of them showed a moderate or severe degree of misalignment. The in silico model accurately predicted the final in vivo position with a correlation coefficient of 0.983 (95%CI, 0.966-0.992), P <.001. Severe CO with right coronary ostium occurred in 3 patients likely due to ostial eccentricity, and CO was not present with the left coronary artery in any of the patients. Mean transaortic gradient was 6.1±3.3mmHg and there were no moderate-severe paravalvular leaks. Conclusions: Patient-specific rotation during valve crimping based on preprocedural computed tomography is feasible with balloon-expandable devices and is associated with the absence of moderate or severe commissural misalignment and left main CO.(AU)


Assuntos
Humanos , Interneurônios Comissurais , Resultado do Tratamento , Estenose da Valva Aórtica , Tomografia Computadorizada por Raios X , Implante de Prótese de Valva Cardíaca , Cardiologia , Espanha , Doenças Cardiovasculares
15.
Rev Esp Cardiol (Engl Ed) ; 76(1): 19-24, 2023 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35570121

RESUMO

INTRODUCTION AND OBJECTIVES: We aimed to describe the feasibility and preliminary outcomes of commissural alignment (CA) for the balloon-expandable transcatheter heart valve. METHODS: The relationship among native commissures and transcatheter aortic valve implantation neocommissures was analyzed in 10 consecutive patients with tricuspid severe aortic stenosis undergoing transcatheter aortic valve implantation after guided implantation based on computed tomography analysis with a self-developed software. CA was predicted by in silico bio-modelling in the 10 patients and the calculated rotation was applied during crimping. Degrees of CA and coronary overlap (CO) were measured through 1-month follow up computed tomography. Transvalvular residual gradients and the rate of paravalvular leak were also analyzed. RESULTS: Mean commissural misalignment was 16.7±8°. Four patients showed mild misalignment but none of them showed a moderate or severe degree of misalignment. The in silico model accurately predicted the final in vivo position with a correlation coefficient of 0.983 (95%CI, 0.966-0.992), P <.001. Severe CO with right coronary ostium occurred in 3 patients likely due to ostial eccentricity, and CO was not present with the left coronary artery in any of the patients. Mean transaortic gradient was 6.1±3.3mmHg and there were no moderate-severe paravalvular leaks. CONCLUSIONS: Patient-specific rotation during valve crimping based on preprocedural computed tomography is feasible with balloon-expandable devices and is associated with the absence of moderate or severe commissural misalignment and left main CO.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/métodos , Desenho de Prótese
16.
JACC Cardiovasc Interv ; 15(23): 2353-2373, 2022 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-36480983

RESUMO

Most transcatheter aortic valve replacement-related procedures (eg, transcatheter aortic valve replacement implantation depth, commissural alignment, coronary access, bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction, paravalvular leak closure) require an optimal fluoroscopic viewing angle located somewhere along the aortic annulus S-curve. Chamber views, coronary cusp and coronary anatomy, can be understood along the aortic annulus S-curve. A better understanding of the optimal fluoroscopic viewing angles along the S-curve may translate into increased operator confidence and improved safety and efficacy while reducing procedural time, radiation dose, contrast volume, and complication rates.


Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
JACC Cardiovasc Interv ; 15(23): 2374-2383, 2022 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-36480984

RESUMO

BACKGROUND: Coronary access may be challenging following transcatheter aortic valve replacement (TAVR) in the setting of transcatheter heart valve (THV) commissural misalignment. OBJECTIVES: The authors aimed to quantify the degree of commissural alignment following balloon-expandable THV implantation using a fluoroscopy-based trigonometric approach and assess its correlation with post-TAVR computed tomography (CT). METHODS: Twenty patients who had undergone both TAVR with the balloon-expandable SAPIEN 3 THV and post-TAVR CT were included in the analysis. Optimized, predeployment 3-cusp angiographic view and postdeployment angiographic view using identical fluoroscopic projections were required. The distance between the most central posterior commissural strut and the THV centerline was assessed. Commissural alignment was calculated by means of a trigonometrical approach using an arcsine function, assuming circular deployment of the THV. Commissural alignment was stratified using a 4-tier scale: aligned (0° to 15°); mildly misaligned (15° to 30°); moderately misaligned (30° to 45°), and severely misaligned (45° to 60°). RESULTS: Seven patients (35.0%) were misclassified by 1 tier, and no patient was misclassified by 2 or more tiers, with strong agreement between CT and fluoroscopy (weighted Cohen's kappa coefficient = 0.724). Correlation of the commissural offset angle determined from fluoroscopy and CT was excellent (r = 0.986; 95% CI: 0.965 to 0.995). Bland-Altman analysis demonstrated a strong agreement between both modalities with a mean difference of 0.5° (95% limits of agreement: -12.7° to 13.7°). CONCLUSIONS: The degree of commissural alignment of the balloon-expandable THV can be reliably assessed and quantified on postdeployment fluoroscopy using a standardized 3-cusp view and trigonometry-based analysis.


Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Valvas Cardíacas , Tomografia Computadorizada por Raios X
18.
Front Cardiovasc Med ; 9: 1056496, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36578836

RESUMO

Objectives: To assess the impact of conventional transcatheter heart valve (THV) commissural alignment techniques on THV/coronary overlap and coronary access (CA) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV). Background: Specific Evolut Pro/Pro + and Acurate Neo2 THV orientations are associated with reduced neo-commissural overlap with coronary ostia in tricuspid aortic anatomy. Whether standard orientation techniques are effective also in the setting of BAV anatomy has not been studied. Methods: The DA VINCI (Definition of trAnscatheter aortic Valve orIeNtation in biCuspId aortic valve) pilot study is a prospective registry enrolling consecutive patients with severe BAV stenosis undergoing TAVR with last generation supra-annular tall-frame THVs implanted with a cusp overlap view-based commissural alignment. Patients underwent pre- and post-TAVR computed tomography (CT) and coronary angiography. The study endpoint was the rate of favorable THV/coronary overlap, defined as an angle > 40° between the THV commissural post and coronary ostia. Other endpoints were the rates of successful THV alignment with respect to the raphe and of selective CA after TAVR. Moreover, different virtual THV alignment models were tested to identify which one would produce the lower degree of THV/coronary overlap. Results: Thirty-four patients with type 1 BAV with right-left raphe undergoing TAVR (23 with Evolut Pro/Pro + and 11 with Acurate Neo2) were included. At pre-TAVR CT, moderate/severe cusp asymmetry was found in 50% of patients, severe coronary ostia eccentricity was observed in 47.1% for the RCA vs. 8.8% for the LCA (P < 0.007). Correct TVH orientation was achieved in 29 cases. At post-TAVR CT, optimal THV alignment/mild misalignment to the raphe was observed in 86.2%, but a moderate/severe overlap with the coronaries was seen in 13.7% for the RCA and 44.8% for the LCA (P = 0.019). After TAVR, selective RCA cannulation was possible in 82.8% vs. 75.9% for the LCA (P = 0.74), while combined selective CA of both coronaries was possible in less than two-thirds of the patients. Virtual THV alignment in the coronary ostia overlap view assuming a hypothetical circular THV expansion would produce an optimal THV/coronary overlap in almost 90% of cases. Conclusion: Given cusp asymmetry and coronary ostia eccentricity of BAV combined with potential THV asymmetrical expansion, conventional commissural alignment techniques are associated with higher rates of THV misalignment and of moderate/severe neo-commissure overlap with the coronary ostia as compared to tricuspid aortic stenosis, resulting in lower rates of selective CA after TAVR. A modified THV orientation technique based on the coronary ostia overlap view might be preferable in BAV patients.

19.
Eur Heart J Case Rep ; 6(10): ytac399, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36225807

RESUMO

Background: Patients with severe aortic stenosis (AS) and complex coronary artery disease with a clinical indication to both transcatheter aortic valve implantation (TAVI) and percutaneous coronary intervention (PCI) pose a clinical dilemma since it is unclear which lesion should be treated first and careful planning is required. Case summary: We report two cases of AS with complex PCI (ASCoP) features. In the first one, easy coronary cannulation with an Acurate Neo2 valve and commissural alignment was predicted; therefore, TAVI was performed first, and subsequently complex high-risk PCI of the left main was performed in the same procedure but without the burden of ongoing severe AS. In the second case, complex coronary cannulation after TAVI with an Evolut PRO valve was predicted; therefore, balloon aortic valvuloplasty and Impella placement were performed first to allow for complex, high-risk multivessel PCI and subsequent TAVI. In both cases, a single-stage approach was preferred to reduce the use of large-bore arterial access with possible consequent adverse events. Discussion: In this case series, we illustrate a possible approach to the treatment of ASCoP patients. In such complex cases, a thorough preprocedural planning is mandatory, and clinical decision-making should be centred upon the predicted chance of cannulation of coronary arteries after TAVI.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...